M12 K-Coded Female Front Mount Power Socket, Solder or Crimp

Xmost M12 K-coded female front mount socket connects an external AC power cable to wiring inside a machine or control enclosure. Rated at 16 A and 630 V, this unshielded M12 power connector offers solder or crimp termination. Choose 2+PE, 3+PE or 4+PE contacts, supplied unwired or with 0.3 m pre-wired leads.

  • Brand: Xmost
  • Connector Size: M12
  • Coding: K-coded
  • Contact Gender: Female
  • Mounting Type: Front mount / front fastened
  • Termination Options: Solder / crimp
    Wiring Options: Unwired / 0.3 m pre-wired leads
  • Contact Options: 3-pin (2+PE) / 4-pin (3+PE) / 5-pin (4+PE)
  • Shielding: Unshielded
  • Power Type: AC
  • Rated Current: 16 A
  • Rated Voltage: 630 V
  • Wire Size Listed: 2.5 mm² / AWG14
  • Panel Mounting Threads: PG9 / M16 × 1.5
  • Standard Listed: IEC 61076-2-111
Category: Tag: Brand:

M12 K-coded female front mount socket provides the equipment-side connection for a compatible M12 K-coded male power cable connector. It mounts to the panel, with solder or crimp termination connecting to the internal power harness.

Select the front fastened version when it matches the enclosure’s mounting design. Choose an unwired socket to terminate your own wires during assembly, or select the 0.3 m pre-wired version for routing to an internal terminal or harness connection.

Three contact arrangements are available. 4+PE means four circuit contacts plus one protective earth contact, giving five contacts in total. Select the arrangement according to the equipment schematic and mating connector.

 Key Features

  • 16 A / 630 V AC power connection: Match these ratings to the equipment circuit.
  • K-coded female interface: Connects to a compatible M12 K-coded male connector.
  • Front fastened mounting: Select according to the panel installation drawing.
  • Solder or crimp termination: Choose the version that matches the harness assembly process.
  • Three contact arrangements: Two, three or four circuit contacts, each with PE.
  • Unwired or 0.3 m leads: Terminate your own wires or use supplied pre-wired leads.
  • PG9 or M16 × 1.5 mounting: Match the mounting thread to the panel opening.
  • Unshielded construction: As specified for this catalogue version.

Product Dimensions

M12 K-Coded Female Front Mount Power Socket, Solder or Crimp

[Insert the front mount female socket drawing and panel cut-out drawing here.]

Illustrated PG9 Version — Dimensions in mm

Item to Check Drawing Value
Mating thread M12 × 1.0
Panel mounting thread PG9
Overall body length shown, excluding leads 20
Upper axial section shown 7
Middle axial section shown 9
Lower axial section shown 2.5
Upper wrench size SW13.4
Mounting nut wrench size SW17.9
Lead length L; according to ordered version

The mating thread connects to the external cable connector. The panel mounting thread secures the socket to the enclosure. Use the cut-out drawing for the selected mounting version.

Needle Arrangement (Front View)

M12 K-Coded Female Front Mount Power Socket, Solder or Crimp 1

[Insert the K-coded female contact arrangement screenshot from page 14 here.]

Configuration Circuit Contacts PE Contact Total Contacts Circuit Positions Used
2+PE 2 1 3 2, 3
3+PE 3 1 4 1, 2, 3
4+PE 4 1 5 1, 2, 3, 4

The diagram shows the mating-face view. The 2+PE version uses circuit positions 2 and 3, together with the protective earth contact.

Product Specifications

Parameter Specification
Product type M12 K-coded female front mount power socket
Mounting Front fastened
Termination options Solder / crimp
Wiring options Unwired / 0.3 m pre-wired leads
Standard listed IEC 61076-2-111
Rated current 16 A
Rated voltage 630 V
Wire size listed 2.5 mm² / AWG14
Shielding Unshielded
Coupling thread M12 × 1.0
Panel mounting thread options PG9 / M16 × 1.5
Insulation resistance ≥100 MΩ
Contact resistance ≤5 mΩ
Recommended coupling torque 0.4 N·m
Maximum coupling torque 0.8 N·m
Temperature range, flexible use −25°C to +80°C
Temperature range, static use −40°C to +80°C
Protection ratings listed IP67 / IP68 / IP69K
Pollution degree 3
Insulator materials listed PA66+GF / TPU+GF

Applications

This M12 K-coded front mount female power connector can be considered for:

  • Machine power panels: Connecting an external AC cable to internal equipment wiring.
  • Industrial control enclosures: Providing a detachable power interface with protective earth.
  • Modular equipment: Allowing the external power cable to disconnect at the housing.
  • Harness production: Selecting solder, crimp or pre-wired construction to match assembly requirements.

Select the configuration according to the circuit ratings, required conductor count and panel design.

7. Wiring and Lead Options

[Insert the wire colour and pin assignment screenshot from page 14 here.]

Contact Position 2+PE 3+PE 4+PE
Pin 1 — Black 1 — BK1 Black 1 — BK1
Pin 2 Black 2 — BK2 Black 2 — BK2 Black 2 — BK2
Pin 3 Black 3 — BK3 Black 3 — BK3 Black 3 — BK3
Pin 4 — — Black 4 — BK4
Pin 5 / PE Yellow/green — YE/GN Yellow/green — YE/GN Yellow/green — YE/GN

“—” means the position is not used. The catalogue lists the yellow/green protective earth lead in the Pin 5 row. Follow the equipment schematic when assigning functions to the numbered black conductors.

Selection and Ordering

Selection Item Available Choices
Contact arrangement 2+PE / 3+PE / 4+PE
Mounting style Front mount
Termination Solder / crimp
Panel mounting thread PG9 / M16 × 1.5
Wiring Unwired / 0.3 m pre-wired
Custom requirements Specify wire type or lead length

Solder and crimp versions have separate ordering references. Specify the termination method when requesting a quotation.

Scroll to Top