Xmost M12 Y-coded female front mount socket connects an external male hybrid cable connector to separate Ethernet signal and power circuits inside the equipment. Combining these contacts in one receptacle allows both connections to pass through a single panel interface.
Select the front fastened version when it matches the enclosure’s installation drawing. Choose an unwired M12 hybrid solder socket for termination during assembly, or the 0.3 m pre-wired version for routing to internal connection points.
Select the configuration by conductor count and current rating. Y3 provides six total contacts with a 12 A power-contact rating. Y4 provides eight total contacts with a 6 A power-contact rating. Signal contacts are rated at 0.5 A in both configurations.
Key Features
- Ethernet and power in one interface: Combines separate signal and power contacts in one M12 panel socket.
- Y3 or Y4 selection: Choose four signal contacts plus two or four power contacts.
- Separate current ratings: Y3 power contacts are rated 12 A; Y4 power contacts are rated 6 A.
- Female Y-coded connection: Mates with a compatible male connector of the matching configuration.
- Solder termination: Supports connection to the internal equipment wiring.
- Unwired or 0.3 m leads: Choose customer termination or supplied pre-wired leads.
- Front fastened mounting: PG9 and M16 × 1.5 panel thread options.
- Unshielded version: As specified on this catalogue page.
Product Dimensions

[Insert the front mount female socket drawing and panel cut-out drawing here.]
Illustrated PG9 Version — Dimensions in mm
| Item to Check | Drawing Value |
|---|---|
| Mating thread | M12 × 1.0 |
| Panel mounting thread | PG9 |
| Overall body length shown, excluding leads | 20 |
| Upper axial section shown | 7 |
| Middle axial section shown | 9 |
| Lower axial section shown | 2.5 |
| Upper wrench size | SW13.4 |
| Mounting nut wrench size | SW17.9 |
| Lead length | L; according to ordered version |
The mating thread connects to the external cable connector. The panel mounting thread secures the socket to the enclosure. Use the cut-out drawing for the selected mounting version.
Needle Arrangement (Front View)

[Insert the Y3 and Y4 female contact arrangement screenshot from page 25 here.]
| Configuration | Signal Contacts | Power Contacts | Total Contacts |
|---|---|---|---|
| Y3 | 4 | 2 | 6 |
| Y4 | 4 | 4 | 8 |
The diagrams show the mating-face view. Match the complete arrangement to the external male connector and equipment wiring specification.
Product Specifications
| Parameter | Specification |
|---|---|
| Product type | M12 Y-coded female front mount hybrid socket |
| Mounting | Front fastened |
| Function | Ethernet signal and power |
| Termination | Solder |
| Wiring options | Unwired / 0.3 m pre-wired leads |
| Standard listed | IEC 61076-2-113 |
| Rated voltage | 50 V AC / 60 V DC |
| Shielding listed | Unshielded |
| Coupling thread | M12 × 1.0 |
| Panel mounting thread options | PG9 / M16 × 1.5 |
| Insulation resistance | ≥100 MΩ |
| Contact resistance | ≤5 mΩ |
| Recommended coupling torque | 0.4 N·m |
| Maximum coupling torque | 0.8 N·m |
| Temperature range, flexible use | −25°C to +80°C |
| Temperature range, static use | −40°C to +80°C |
| Protection ratings listed | IP67 / IP68 / IP69K |
| Pollution degree | 3 |
| Insulator materials listed | PA66+GF / TPU+GF |
Ratings and Wire Sizes by Configuration
| Parameter | Y3 | Y4 |
|---|---|---|
| Contact arrangement | 4 signal + 2 power | 4 signal + 4 power |
| Power-contact rated current | 12 A | 6 A |
| Signal-contact rated current | 0.5 A | 0.5 A |
| Power wire size listed | 2 × 1.5 mm² / AWG16 | 4 × 0.5 mm² / AWG20 |
| Signal wire size listed | 4 × 0.14 mm² / AWG26 | 4 × 0.14 mm² / AWG26 |
The power-contact current rating does not apply to the signal contacts.
Applications
This M12 Y-coded front mount female hybrid connector can be considered for:
- Ethernet-enabled equipment: Bringing signal and power wiring through one panel interface.
- Automation modules: Connecting an external hybrid cable to internal circuits.
- Modular machinery: Providing a detachable signal-and-power connection at the housing.
- Equipment with limited panel space: Combining the specified circuits in one receptacle.
Confirm the complete assembly’s network performance, power loading and shielding requirements before selection.
Wiring and Lead Options
[Insert the wire colour and pin assignment screenshot from page 25 here.]
| Pin | Y3 Wire Colour | Y4 Wire Colour |
|---|---|---|
| 1 | White/orange — WH/OR | White/orange — WH/OR |
| 2 | Orange — OR | Orange — OR |
| 3 | White/green — WH/GN | White/green — WH/GN |
| 4 | Green — GN | Green — GN |
| 5 | Blue — BU | Blue — BU |
| 6 | White — WH | White — WH |
| 7 | — | Brown — BN |
| 8 | — | Black — BK |
“—” means the contact is not present. Follow the numbered contact diagram and equipment schematic for signal functions and power polarity.
Selection and Ordering
| Selection Item | Available Choices |
|---|---|
| Contact arrangement | Y3 / Y4 |
| Mounting style | Front mount |
| Panel mounting thread | PG9 / M16 × 1.5 |
| Termination | Solder |
| Wiring | Unwired / 0.3 m pre-wired |
| Custom requirements | Specify wire type or lead length |
Example enquiry: M12 Y-coded female front mount hybrid socket, Y3, PG9 mounting, solder termination, 0.3 m pre-wired leads.