Xmost M12 M-coded male rear mount socket provides an external threaded power connection with wire termination inside the equipment enclosure. Its rear fastened construction suits panels designed to accommodate the rear mounting hardware and internal harness access.
This M12 male power socket is available in four configurations, providing two to five circuit contacts plus PE. The contact positions vary between configurations, so selection should follow the required circuit arrangement and matching cable interface.
Choose an unwired M12 solder socket for termination during assembly or a pre-wired version for routing to an internal connection point. Listed lead lengths of 0.1 m, 0.3 m and 0.5 m support different enclosure layouts.
Key Features
- Rear fastened panel mounting: For housings designed around a rear mount power receptacle.
- Male M-coded interface: Connects to a compatible M12 M-coded female cable connector.
- Protective earth configurations: 2+PE, 3+PE, 4+PE and 5+PE options.
- Solder wiring connection: For termination to the internal equipment harness.
- Pre-wired lead choices: 0.1 m, 0.3 m and 0.5 m versions listed.
- AC power ratings: Rated current of 8 A and rated voltage of 630 V.
- Mounting thread selection: M12 × 1.0, PG9 and M16 × 1.5.
- Unshielded design: Matches the specification for this product version.
Product Dimensions

[Insert the rear mount male socket dimension drawing and corresponding panel cut-out here.]
Dimensions for the Illustrated PG9 Version
| Drawing Item | Dimension / Specification |
|---|---|
| Mating thread | M12 × 1.0 |
| Panel mounting thread | PG9 |
| Upper wrench size | SW17 |
| Lower wrench size | SW13.4 |
| Upper axial section shown | 11 |
| Overall body length shown, excluding leads | 20.4 |
| Flange thickness shown | 2 |
| Lower axial section shown | 7 |
| Lead length | L, according to ordered version |
| Unit | mm |
Check the available space for rear fastening hardware and lead routing. Prepare the panel opening using the drawing for the ordered mounting thread.
Needle Arrangement (Front View)

[Insert the M-coded male needle arrangement screenshot from page 19 here.]
| Configuration | Contact Composition | Positions Used in the Wiring Table |
|---|---|---|
| 3-pin (2+PE) | 2 circuit contacts + PE | 2, 4 and PE |
| 4-pin (3+PE) | 3 circuit contacts + PE | 1, 3, 5 and PE |
| 5-pin (4+PE) | 4 circuit contacts + PE | 1, 2, 4, 5 and PE |
| 6-pin (5+PE) | 5 circuit contacts + PE | 1, 2, 3, 4, 5 and PE |
Identify the terminals from the mating-face diagram. Use the complete contact arrangement when checking compatibility with the external cable.
Product Specifications
| Parameter | Specification |
|---|---|
| Brand | Xmost |
| Product type | M12 M-coded male rear mount socket |
| Mounting method | Rear fastened |
| Application type | AC power |
| Contact configurations | 2+PE / 3+PE / 4+PE / 5+PE |
| Termination | Solder |
| Wiring options | Unwired / pre-wired leads |
| Standard listed | IEC 61076-2-111 |
| Rated current | 8 A |
| Rated voltage | 630 V |
| Insulation resistance | ≥100 MΩ |
| Contact resistance | ≤5 mΩ |
| Shielding | Unshielded |
| Coupling thread | M12 × 1.0 |
| Panel mounting thread options | M12 × 1.0 / PG9 / M16 × 1.5 |
| Recommended coupling torque | 0.4 N·m |
| Maximum coupling torque | 0.8 N·m |
| Wire size listed | 1.5 mm² / AWG16 |
| Temperature range, flexible use | −25°C to +80°C |
| Temperature range, static use | −40°C to +80°C |
| Protection ratings listed | IP67 / IP68 |
| Pollution degree | 3 |
| Insulator materials listed | PA66+GF / TPU+GF |
Applications
This M12 M-coded rear mount solder socket can be considered for:
- AC-powered equipment housings: Connecting an external supply cable to internal power wiring.
- Control enclosures with rear mounting access: Accommodating the rear fastening hardware and harness connection.
- Pre-wired machine assemblies: Routing socket leads to an internal terminal or harness.
- Modular equipment power interfaces: Providing a detachable connection at the panel.
- Circuits requiring protective earth: Selecting a contact arrangement with the required circuit contacts and PE.
Check the equipment’s electrical requirements and rear installation clearance before selecting the version.
Wiring and Lead Options
[Insert the wire colour and pin assignment screenshot from page 19 here.]
| Contact Position | 2+PE | 3+PE | 4+PE | 5+PE |
|---|---|---|---|---|
| Pin 1 | — | Black 1 — BK1 | Black 1 — BK1 | Black 1 — BK1 |
| Pin 2 | Black 2 — BK2 | — | Black 2 — BK2 | Black 2 — BK2 |
| Pin 3 | — | Black 3 — BK3 | — | Black 3 — BK3 |
| Pin 4 | Black 4 — BK4 | — | Black 4 — BK4 | Black 4 — BK4 |
| Pin 5 | — | Black 5 — BK5 | Black 5 — BK5 | Black 5 — BK5 |
| Pin 6 / PE | Yellow/green — YE/GN | Yellow/green — YE/GN | Yellow/green — YE/GN | Yellow/green — YE/GN |
The yellow/green conductor is the PE lead. Follow the selected contact diagram and equipment schematic when connecting the numbered black conductors.
Selection and Ordering
Specify:
- M-coded male, rear mount.
- Required contact configuration.
- Panel mounting thread.
- Unwired or pre-wired version.
- Lead length: 0.1 m, 0.3 m or 0.5 m.
- Any custom wiring requirements.
Confirm the matching external connector and allow space for the rear mounting hardware and leads.