M12 A-Coded Female Straight Shielded Molded Cable Connector

Xmost M12 A-coded female straight connector is a shielded, single-ended molded cable assembly for compatible sensor and actuator connections. Available in 3-, 4-, 5-, 8-, 12- and 17-pin configurations, this M12 female sensor connector features a straight cable exit, M12 screw locking and PVC or PUR cable options.

  • Brand: Xmost
  • Connector Size: M12
  • Coding: A-coded
  • Contact Gender: Female
  • Contact Configurations: 3-pin / 4-pin / 5-pin / 8-pin / 12-pin / 17-pin
  • Assembly Type: Single-ended molded cable assembly
  • Connector Orientation: Straight
  • Shielding: Shielded
  • Application: Sensors and Actuators
  • Standard: IEC 61076-2-101
Category: Tag: Brand:

Xmost M12 A-coded female straight shielded cable connector provides a preassembled connection to equipment with a matching A-coded male interface. Its single-ended molded construction integrates the female connector and cable into one assembly.

The straight cable exit directs the cable along the mating axis, supporting installations with clearance behind the connection. M12 × 1.0 screw locking secures the mating interface.

This shielded M12 sensor cable assembly is available in six contact configurations. Electrical ratings and wire sizes vary by pin count. PVC and PUR cable options are listed in 1 m and 3 m lengths.

Key Features

  • M12 A-coded female interface for compatible sensors and actuators.
  • Shielded cable assembly for equipment requiring a shield connection.
  • Straight molded connector for axial cable routing.
  • Single-ended preassembled cable construction.
  • 3-, 4-, 5-, 8-, 12- and 17-pin configurations.
  • M12 × 1.0 screw-locking interface.
  • PVC or PUR cable options, with 1 m and 3 m catalog lengths.

Product Dimensions

M12 A-Coded Female Straight Shielded Molded Cable Connector

Dimensions (mm)

Dimension Value
Connector axial length shown 45.4
Coupling section axial span 13.4
Molded body axial span 32
Coupling outside diameter Ø14.5
Cable-exit width shown 12.9
Maximum cable outside diameter ≤ Ø8.0
Mating thread M12 × 1.0

Dimensions correspond to the marked spans in the straight female connector drawing. Cable length is specified separately.

Product Specifications

Electrical Ratings by Contact Configuration

Contact Configuration Rated Current Rated Voltage Wire Size
3-pin 4 A 250 V 0.34 mm² / AWG22
4-pin 4 A 250 V 0.34 mm² / AWG22
5-pin 4 A 60 V 0.34 mm² / AWG22
8-pin 2 A 30 V 0.34 mm² / AWG22
12-pin 1.5 A 30 V 0.25 mm² / AWG24
17-pin 1.5 A 30 V 0.14 mm² / AWG26

General Specifications

Parameter Specification
Brand Xmost
Connector Size M12
Coding A-coded
Contact Gender Female
Connector Orientation Straight
Assembly Type Single-ended molded cable assembly
Shielding Shielded
Application Listed Sensors and Actuators
Standard Listed IEC 61076-2-101
Locking Method M12 × 1.0 screw locking
Contact Termination Soldering
Insulation Resistance ≥ 100 MΩ
Contact Resistance ≤ 5 mΩ
Recommended Tightening Torque 0.4 N·m
Maximum Tightening Torque 0.8 N·m
Dynamic Operating Temperature −25 °C to +80 °C
Static Operating Temperature −40 °C to +80 °C
Protection Ratings Listed IP67 / IP68
Pollution Degree 3
Insulator Material Options PA66 + GF / TPU + GF

Applications

Suggested applications for this M12 A-coded female straight shielded sensor connector include:

  • Industrial sensors: Connections to devices with compatible A-coded male interfaces.
  • Actuator wiring: Cable connections to equipment with matching pin arrangements and electrical requirements.
  • Automation equipment: Shielded field-device wiring between compatible sensors, actuators and I/O modules.
  • Multi-contact device connections: Equipment requiring the selected 8-, 12- or 17-pin arrangement.
  • Axial cable-routing layouts: Installations where the cable can exit directly behind the connector.

Select the pin count, electrical ratings, wire assignment and shielding arrangement to match the connected equipment.

Selection and Ordering

Specify the contact configuration, cable jacket and cable length. Select the corresponding shielded straight female part number from the catalog ordering table.

Match the A-coded interface and pin arrangement to the equipment. Follow the female connector’s front-view pin diagram and wire-color assignment, and maintain the specified shield connection during installation.

Reviews

There are no reviews yet.

Be the first to review “M12 A-Coded Female Straight Shielded Molded Cable Connector”

Your email address will not be published. Required fields are marked *

Scroll to Top